| Type |
Humidity Sensor |
| is_customized |
Yes |
| Material |
Mixture |
| Usage |
Temperature Sensor |
| Theory |
Inductance Sensor |
| Output |
Digital Sensor |
| Model Number |
pt100 |
| Introduction |
| SBWR thermocouple temperature transmitter , SBWZ RTD temperature transmitter is DDZ-S series of instruments in the field mounted temperature transmitter unit . It uses a two-wire transmission mode ( two wires for power input , the common signal output transmission line ) . Thermocouple , RTD input signal is converted into an electrical signal or the measured temperature or into a linear output signal 4 ~ 20mA , the transmitter can be mounted on a thermocouple , thermal resistance of the junction box with the formation of an integrated structure . It is a new generation Thermometer can be widely used in metallurgy , petrochemical , power, light industry, textile, food, defense, and scientific research and other industrial sectors .
Second, the temperature transmitter features
1, using epoxy sealed structure, seismic, temperature, suitable for installation in harsh field environments .
2 , on-site installation in thermal resistance, thermocouple junction box , direct output 4 ~ 20mA, so not only eliminates the need for expensive wire compensation costs , and improve the long-distance signal transmission process, anti-interference ability .
3, high accuracy , low power consumption , wide temperature range , stable and reliable .
4 , range adjustable , and has a more positive function linearization , thermocouple temperature transmitter has automatic cold junction compensation. A wide range of applications , both with thermocouple , RTD structure to form an integrated on-site installation , but also as a functional module installed into the detection device.
Third, the main technical indicators :
1, Input : RTD Pt100, Cu50, Cu100
Thermocouple K, E, S, B, T, J, N
2 , Output: 4 ~ 20mA DC signal with the output resistance of the signal into a linear thermal resistance thermometer , the temperature signal can be input into a linear thermal resistance thermometer in the range ; millivolt signal is linear with thermocouple input You can also enter into a linear thermocouple temperature signal thermometer .
3 , the basic error : 0.2%, 0.5%
4 , transmission: wire
5 , the transmitter minimum operating supply voltage 12V, maximum 35V, rated working voltage of 24V.
6 Load : Extreme Negative load resistance is calculated as follows
RL (max) = 50 × (Vmm-12)
That is when the 24V load resistance can be selected within the range of 0 ~ 600 ) Rated load 250.
Note : Range of adjustable transmitter, zero and span changes required repeated testing of full scale ; galvanic transmitter before commissioning must warm up for 30 minutes.
7 , ambient temperature 0.05% 1
8 , the normal working environment:
a, ambient temperature -25 ~ +80
b, Relative Humidity 5 % to 95%
c, f 55Hz mechanical vibration amplitude <0.15mm
Fourth, model , category :
| Model |
Sensor indexing number |
Maximum range requirement |
Prescribed minimum range ( difference between the upper and lower limit ) |
| SBWR-2160 |
E |
0 ~ 800 |
300 |
| SBWR-2260 |
K |
0 ~ 1300 |
400 |
| SBWR-2360 |
S |
0 ~ 1600 |
600 |
| SBWR-2460 |
B |
0 ~ 1800 |
800 |
| SBWR-2560 |
T |
0 ~ 400 |
200 |
| SBWR-2660 |
J |
0 ~ 1200 |
300 |
| SBWR-2760 |
N |
0 ~ 1200 |
400 |
| SBWR-4160 |
E |
0 ~ 800 |
300 |
| SBWR-4260 |
K |
0 ~ 1300 |
400 |
| SBWR-4360 |
S |
0 ~ 1600 |
600 |
| SBWR-4460 |
B |
0 ~ 1800 |
800 |
| SBWR-4560 |
T |
0 ~ 400 |
200 |
| SBWR-4660 |
J |
0 ~ 1200 |
300 |
| SBWR-4760 |
N |
0 ~ 1200 |
400 |
| SBWZ-2160 |
Cu50 |
-50 ~ 150 |
50 |
| SBWZ-2260 |
Cu100 |
-50 ~ 150 |
50 |
| SBWZ-2460 |
Pt100 |
0 ~ 600 |
50 |
| SBWZ-2460 |
Pt100 |
-100 ~ 200 |
50 |
| SBWZ-4460 |
Pt100 |
-200 ~ 600 |
|
Scope of application:
Can receive various types of thermal resistance or thermocouple input, can be directly installed in the temperature sensor junction box, and mark the standard voltage and current signals, is widely used in control field of electric power, metallurgy, chemical industry, food, pharmaceutical, environmental protection and other industries.
Factory direct SWBZ thermal resistance temperature transmitter
Output: 4 ~ 20mA (can do 0-5V 0-10V price separately)
The accuracy of:0.5%
Power supply: 24VDC
Temperature range: 0 ~ 50 0 ~ 100 0 ~ 150 0 ~ 200 0 ~ 300 0 ~ 400(Please note the required temperature range.)
Function characteristics:
The transmitter signal power with two common wire, saves the thermocouple special compensation wire, reduce theerror brought by the line interference.
Small volume, easy installation
Good precision, anti-jamming, stability, maintenance free
External can directly adjust the zero and full scale
Current signal output, far transmission distance, shorten the instrument and sensor distance, reduce the errorbrought by the line interference
The main technical indicators:
Output: 4 ~ 20mA, the limit of 28 mA
The input range: thermal resistance: Pt100 0-150
Fuse detection: the upper (standard)
The measurement accuracy: thermal resistance: ± 0.2%FS
Temperature drift: ± 0.2%/
The cold end compensation: 0 ~ 50 ± 1
Methods: adjust potentiometer
The power supply voltage: 24VDC ± 10%
Load capacity: 0 ~ 500.
Environment temperature: -20 ~ 80
Humidity: < 85%RH