| Type | Humidity Sensor |
| is_customized | Yes |
| Output | Digital Sensor |
| Usage | Temperature Sensor |
| Material | Mixture |
| Theory | Inductance Sensor |
Temperature and humidity sensors
DHT22
New Model : AM2302
-
Relative humidity and temperature measurements
-
All calibrated digital output
-
Excellent long-term stability
-
No additional components
-
Long distance signal transmission
-
Ultra-low power
-
4Pin Installation
-
Completely interchangeable
DHT22Product Overview
DHT22Digital temperature and humidity sensor is a calibrated digital signal output of the temperature and humidity combined sensor . It uses a dedicated digital modules capture technology and the temperature and humidity sensor technology to ensure that products with high reliability and excellent long-term stability. Sensor includes a capacitive sense - and a wetNTCTemperature measurement devices , and with a high-performance8Bit microcontroller connected . Therefore, the product has excellent quality, fast response , anti-interference ability , high cost and other advantages. EachDHT22Sensors are calibrated in a precision humidity calibration chamber. Calibration coefficients stored in the form of a programOTPMemory, internal sensor detection signal in the process to call these calibration coefficients. Single-wire serial interface , the system integration becomes simpler and quicker . Ultra- small size , low power consumption , signal transmission distance up20Meters, making all kinds of applications and even the most demanding applications the best choice is . Products4Pin single row pin package . Easy connection, special packages according to user needs and available.
Applications
-
HVAC
-
Test and inspection -
-
Car
-
Data Logger
-
Consumer goods
-
Automatic control
-
Stations
-
Appliances
-
Humidifiers
-
Medical
-
Dehumidifier
1The sensor performance specifications
Parameter | Condition | Min | Typ | Max | Unit |
Humidity |
Resolution | | | 0.1 | | % RH |
| 16 | | Bit |
Repeatability | | | 1 | | % RH |
Accuracy | 25 | | 2 | | % RH |
-20-80 | | | 5 | % RH |
Interchangeability | Fully interchangeable |
Sampling period | | 1.7 | 2 | | S |
Response time | 1 / e (63%) 25, 1m / sAir | | < 5 | | S |
Sluggish | | | <0.5 | | % RH |
Long-term stability | Typical values | | <0.5 | | % RH / yr |
Temperature |
Resolution | | | 0.1 | |